Highly rated on Google Reviews & Home Advisor ★★★★
logo action air
Midland & Odessa

My AC is Not Blowing Cool Air

Let’s tackle a hot topic today – literally! Have you ever experienced the frustration of your air conditioner deciding it’s just not going to blow cool air anymore? It’s like having a popsicle on a scorching day, only to find out it’s melted before you even take a bite. But don’t sweat it! At Action Air Plumbing & Septic in Midland, TX, we’re all about keeping your home cool and comfy, even in the hottest Texas summers. In this blog, we’ll dive into some handy troubleshooting tips and tricks to get your air conditioner back in action, blowing refreshing cool air like it should. Say goodbye to heat and hello to comfort – let’s get started!

 

We’re here to help you with 15 troubleshooting tips for your AC not blowing cool air before you call the Midland professionals at Action Air Plumbing & Septic.

  1. The first thing to check is the thermostat settings. Please double-check that the system is on and set to cool and that the temperature setting has not been inadvertently changed. You can also change out the batteries in the thermostat, especially if the thermostat is malfunctioning. If any settings are incorrect, make the appropriate adjustments and let the system kick back on. Give it a few minutes to adjust, and then check that cool air is blowing out from the vents. If you feel cool air, you’ve fixed the problem! If not, let’s move on with our troubleshooting.



  1. Very often, the fix is quite simple. Have you checked the air filter lately? A check of this may fix your problem. Turn the system off and remove your air filter for inspection. Since the air filter catches dust, dirt, and other airborne particles, a dirty air filter can block airflow and cause your AC to not blow cool air through your vents. If the air filter appears dirty, replace the filter and see if this fixes the issue.

 

  1. In some houses, the Furnace/AC unit is wired to a switch in your utility room. Double-check that no power switch in your utility room has been switched off.



  1. The next likely reason your AC is not blowing cool air is your circuit breaker. Often, there is a separate breaker for the indoor and outdoor AC units. Check to ensure all appropriate breakers are switched on.


  2. Lack of maintenance on your outdoor unit can cause many issues with your unit. Complete a visual inspection of the area and ensure at least 2 feet of space around the unit. You may need to remove leaves, branches, or debris around the unit. If you haven’t had your unit serviced recently, it may be a great time to call on the experts at Action Air Plumbing & Septic for a professional inspection and maintenance. We offer a Preventative Maintenance Agreement for affordable maintenance bi-annually with multiple payment options. Call us at (432)620-8900 to learn more about our Preventative Maintenance Agreement and its benefits.



  1. Clearing away the leaves, branches, and other debris around the unit will also be helpful if you have a blocked condenser fan. The condenser fan brings air into the outdoor unit and through the condenser coil to pull heat from the home. If there is debris accumulated between the fans, this can clog the coil and reduce energy efficiency, and lead to your AC not blowing cool air.

  2. A dirty condenser coil may also be causing the issue. The condenser coil wraps around the outdoor unit condenser and can also accumulate dirt, filth, and debris, which will restrict important heat transfer.



  1. Check your outdoor disconnect. This box is mounted near the outside AC unit and is a safety feature that can shut off the electrical unit. If the disconnect power is shut off, turn it back on. You can also check for damaged or faulty issues that may be causing an issue and will require a call to the professionals at the Indoor Comfort Team.




  2. A dirty or frozen evaporator coil may be the problem causing your AC to run but not cool the air. When an evaporator coil is dirty, it blocks the heat transfer from the air to the refrigerant and causes the coil to freeze. Some signs of a frozen evaporator coil are frost formed on the copper refrigerant tubing, increased utility bills, and the system not adequately cooling. If this is the case, turn the AC off and allow your system to run on ‘fan only’ until the coil is no longer frozen, and then turn the AC back on.



  1. A dirty indoor fan motor can also create problems, leading your AC to not blow cool air. When this fan is dirty, the fan cannot pull enough hot air into the unit to cool your home adequately. This fan cleaning can be completed by one of our HVAC pros. Give us a call at (432)620-8900, and we’d be happy to help!



  1. Another potential source of your issue is a clogged condensation drain hose. The condensation drain hose removes moisture from the condensation created when the AC removes the humidity and directs it outside the home or to a floor drain. These drain hoses can become blocked by mold or algae growth, but this can be easily removed by a small screwdriver or something similar to clear the clog. If you find a clog high in the line, using suction from a wet/dry shop vac can often remove it.

  1. Sometimes, a refrigerant leak may be your problem. This chemical is crucial for the cooling process, and a leak can cause your unit not to blow cool air, run for longer periods, and cause damage to your compressor or a system shutdown. Call Action Air Plumbing & Septic at (432)620-8900 for a guaranteed fix if you suspect a refrigerant leak.

  2. If you have air blowing out of your vents but your house is not cooling, a leak in the ductwork may be the cause. Ductwork leaks can lead to the cold air escaping before it reaches rooms, causing it to feel uncomfortably warm while other rooms feel colder. Finding the leak and fixing the ductwork can help with efficiency and performance. Call us, and we’d love to send out one of our knowledgeable techs to diagnose the issue – https://actionairplumbing.com/get-appointment/



  1. A faulty compressor, a broken capacitor, a malfunctioning contactor, and a faulty condenser fan motor are all parts of your outdoor unit that can malfunction and lead to the air from the vents not being cool in your home.



  1. Last but certainly not least, it may be time to look at replacing your AC unit due to age or insufficient capacity to cool your home. Call on the experts since 1985, Action Air Plumbing & Septic, to get a quote for a new system! We will discuss all your wants and needs to help you select a new, properly sized unit to keep you super cool all summer long.

 

As we wrap up, remember that keeping your home cool and comfortable is our top priority at Action Air Plumbing & Septic in Midland, TX. If you’ve tried out troubleshooting tips and your air conditioner still isn’t blowing cool air, don’t hesitate to reach out to our team at (432)620-8900. We’re here to ensure your indoor environment remains refreshing and pleasant, no matter the heat outside. Let’s work together to get your AC back in tip-top shape and keep you cool all summer long!